Pasar al contenido principal
  • Socios aprobados
  • Acerca de ELGA
    • Acerca de ELGA
    • Empleo
    • Eventos
  • Soporte
    • Registrar un producto
    • Register Your Product (USA & Canada Only)
  • Contacto
  • English
  • Deutsch
  • Français
  • Italiano
  • Português
  • 日本語
  • 中文
Inicio ELGA LabWater
  • Productos
    • PURELAB
    • CENTRA
    • MEDICA
    • BIOPURE
    • Gama completa de productos ELGA
  • Aplicaciones
    • Análisis microbiológico
    • Bioquímica clínica
    • Cromatografía de gases
    • Cromatografía líquida
    • Cultivos celulares
    • Electroquímica
    • Espectrofotometría
    • Espectrometría de masas
    • Espectroscopia atómica
    • Genética
    • Inmunoquímica
    • Requisitos generales de agua de laboratorio
  • Tecnologías
    • Carbón activado
    • Electrodesionización (EDI)
    • Filtración
    • Intercambio iónico
    • PureSure
    • Ultravioleta
    • Ósmosis inversa
  • Impurezas en el agua
    • Compuestos inorgánicos
    • Compuestos orgánicos
    • Gases disueltos
    • Microorganismos y bacterias
    • Partículas
  • Planificación de laboratorio
  • Knowledge
    • Blog
    • Casos prácticos
    • Agua ultrapura
    • Manuales e informes técnicos
  • Productos
    • PURELAB
      • PURELAB® flex 1 y 2
      • PURELAB® flex 3 y 4
    • CENTRA
      • CENTRA® 60/120
      • CENTRA® RDS
      • CENTRA® R200
    • MEDICA
      • MEDICA® 7/15
      • MEDICA® EDI 15/30
      • MEDICA® Pro EDI 60/120
      • MEDICA® Pro-LPS
      • MEDICA® Pro-R y Pro-RE
      • MEDICA® R200
    • BIOPURE
      • BIOPURE 7/15
      • BIOPURE 60/120
      • BIOPURE 200/300/600
    • Gama completa de productos ELGA
      • PURELAB® Classic
  • Aplicaciones
    • Análisis microbiológico
    • Bioquímica clínica
    • Cromatografía de gases
    • Cromatografía líquida
    • Cultivos celulares
    • Electroquímica
    • Espectrofotometría
    • Espectrometría de masas
    • Espectroscopia atómica
    • Genética
    • Inmunoquímica
    • Requisitos generales de agua de laboratorio
  • Tecnologías
    • Carbón activado
    • Electrodesionización (EDI)
    • Filtración
    • Intercambio iónico
    • PureSure
    • Ultravioleta
    • Ósmosis inversa
  • Impurezas en el agua
    • Compuestos inorgánicos
    • Compuestos orgánicos
    • Gases disueltos
    • Microorganismos y bacterias
    • Partículas
  • Planificación de laboratorio
  • Knowledge
    • Blog
      • Analytical Chemistry
      • Clinical & Pharma
      • Cool Science
      • Environment and sustainability
      • Life in the lab
      • Purelab product design
      • Science of the future
      • Water Purity
      • Water in the lab
    • Casos prácticos
      • Abbott Diagnostics elige sistemas ELGA MEDICA en el sur de Asia
      • Beam Me Up, Scotty: PURELAB® Option Q Delivers Essential Ultra Pure Water
      • Clean Water for a Clean Future
      • Critital Tests Benefit from PURELAB® Option Reliable Pure Water
      • DASA: la mayor empresa de diagnóstico médico de Brasil
      • ELGA ayuda a los laboratorios de inmunoserología a maximizar el tiempo de actividad
      • Fondazione Telethon Continues to Choose ELGA Labwater as a Trusted Partner
      • La importancia del agua ultrapura de tipo 1+ para el desarrollo de medicamentos genéricos
      • Seleccionan MEDICA® Pro para los analizadores Siemens ADVIA® del City General Hospital
      • Optimale Wasserqualität für mikrobiologische Forschung und Lehre
      • PURELAB® Option R Guarantees Pure Water for Leading Microfluidics Technology
      • PURELAB® Pulse Delivers Reliable Water Quality and Quantity for a Wide Range of Applications
      • PURELAB® flex: un sistema de formación ideal para el método de investigación actual
      • Powering Cutting-Edge Gene Research
      • Sichere Reinstwasserversorgung für präzise Produkttests
      • Zentrale Reinstwasser-Aufbereitung für Analyser
      • ELGA LabWater and Beckman Coulter Join Forces
      • Applied New Technologies Department Improves ICP, IC & HPLC Sample Turnaround Times with PURELAB®
      • Descubrir los secretos de la Antártida con ayuda del agua ultrapura
      • Advancing Genetic Technologies
      • Cross Infection Control: Pure and Simple
      • Researching effective new ways to prevent cardiovascular disease at the University of Columbia
    • Agua ultrapura
    • Manuales e informes técnicos
      • Pureza de agua de HPLC
      • HPLC en farmacia
      • Reducción del riesgo clínico
      • Sostenibilidad
  • English
  • Deutsch
  • Français
  • Italiano
  • Português
  • 日本語
  • 中文
  • Política de privacidad
  • Términos y condiciones
  • Cumplimiento legal internacional
  • Patentes
  • Aviso legal
  • Inicio
  • Node
  • Different Types of Pure Water For The Lab: What You Need to Know
Water Purity
Water In The Lab

Different Types of Pure Water For The Lab: What You Need to Know

26 Mar 2021
- by ELGA Editorial Team

Microscopic Water Bubbles

As you may know, there a several types of water purity available depending on what you’re tackling at the bench. This includes a range from Type III for general use such as rinsing out your beakers, all the way up to Type I+ for sensitive applications like the intriguingly sounding ‘graphite furnace atomic absorption spectrometry’ (GF-AAS).

A Quick Guide to Pure Water Types:

Making the decision on which type of pure water you need for your application can be challenging. Knowing this informs the purification technology you use and systems you require to produce the right water grade.

As we’ve said, there are several different types of water, however at ELGA we specialise in the production of three types in particular: Type I, Type II and Type III.

Diagram showing the different types of water used in the lab: ultrapure water, pure water and primary grade water.
Diagram showing the different types of water used in the lab: ultrapure water, pure water and primary grade water. (c) ELGA LabWater 2020

Type 1 Water (Ultrapure Water)

Type I grade water, also known as Ultrapure Water, is the purest form of water to be produced. It’s used for the most critical applications and advanced analytical procedures.
This includes:
• Cell and Tissue Cultures
• Liquid Chromatography, including High Performance Liquid Chromatography (HPLC)
• Gas Chromatography
• Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
• Molecular Biology
Type I can also be used in applications that require Type II water. This is quite a common practice that can help to avoid the generation of by-products during applications.

Type 2 Water

Type II water grade doesn’t have the same pureness of Type I, but still maintains high levels of purity. It is a good feed water for clinical analyzers as the calcium build-up is reduced with this water type.
It can also be used in applications such as:
• General Lab Practices
• Microbiological Analysis and preparation
• Electrochemistry
• FAAS
• General Spectrophotometry
It can also be used as feed water for Type I water production.

Type 3 Water (RO Water)

Type III grade water, also known as RO water, is water produced through the purification technology reverse osmosis. Of all the pure water types it has the lowest level of purity, but is typically the starting point for basic lab applications, such as cleaning glassware, heating baths or media preparation. It can also be used as a feed water for Type I water production.

How is Laboratory Water Purity Assessed and Defined?

​To implement a coherent classification system for water purity, we make use of several key factors describing the various properties of water.

The Conductivity of Water

Conductivity is reported as microSiemens per centimeter (µS/cm) at 25oC and is the reciprocal of resistivity and provides a measure of a fluid's ability to conduct electrical current. Conductivity is typically used when assessing water ranging from 'raw water' through to 'drinking water' and provides a valuable, non-specific indication of the level of ions in the water.

The Resistivity of Water

Reported as Mega-Ohms per centimeter (MO-cm) at 25oC, resistivity is related to conductivity: a high resistivity equals a low conductivity. As such, it also provides a measure of the water's ionic content. Unlike conductivity, resistivity is primarily used in the assessment of ultrapure water.

Organic Compound Levels in Water

Organic compounds can exist in water in numerous forms and so measuring every single one individually is impractical. Instead, the most useful indicator is considered to be the total organic carbon (TOC) content of the solution. This is measured via a process that oxidizes the organic compounds present and then quantifies the oxidation products generated. TOC is as close as we can currently get to a 'universal indicator' for the presence of organic impurities.

Alternatively, chromatographic techniques may be employed to determine the specifics of organic content, but this is frequently considered both too expensive and time-consuming to be used in general monitoring workflows.

Biological Contamination of Water

The presence of biological contaminants such as bacteria and other microorganisms is a common issue in untreated water. Bacterial levels reported as colony forming units per milliliter (CFU/ml) are kept low via filtration, UV treatment and sterilant solutions.

Following an incubation period in suitable growth media, individual bacterial species and total viable cell counts can be determined. Bacteria counts may also be monitored through the use of epifluorescence testing to rapidly detect and distinguish between dead and living microorganisms.

In addition to the bacteria themselves, endotoxins produced from the cell wall of gram-negative microorganisms (reported as endotoxin units per milliliter, EU/ml; 1 EU/ml approximately equal to 0.1 ng/ml) can be assessed using standard tests based on Limulus Amebocyte Lysate activity.

The Presence of Colloids in Lab Water

Suspended particles can cause water turbidity (measured in Nephelometric Turbidity Units, NTU) and are therefore filtered out of laboratory water as much as possible. This colloidal material is defined as being less than 0.5 µm in size and may contain iron, silica, aluminium or organic materials. The Fouling Index (FI) is frequently used to estimate the potential of water to block filters under 0.45 µm filter conditions.

Boards Setting the Standards of Water Purity

There are several international boards around the world that have been working to establish some degree of consistency in the standards of water purity – the more people we have agreeing to these standards, the easier it is to generate reproducible data. Some labs will also adopt standards as outlined by the regulatory body overseeing the region they work in, for example, as found in the European, US or Japanese Pharmacopoeias. However, very few of these standards are specific to a particular application.

Clinical and Laboratory Standards Institute (CLSI) – formerly NCCLS

As of 2006, the CLSI has moved away from the typical Type I, II and III designations, instead preferring to suggest that water be simply ‘fit for purpose’, and only describes one grade in significant detail: Clinical Reagent Laboratory Water. The CLSI has also briefly outlined other grades in less detail, such Special Reagent Water (SRW) and instrument feed water.

International Organization for Standardization (ISO)

The ISO based its specification on ISO 3696:1987, and specifies three grades of water: Grade 1, Grade 2 and Grade 3, where Grade 1 is the most pure (see below):

Water quality parameters for ISO grades

Parameter

Grade 1

Grade 2

Grade 3

pH value at 25oC

–

–

5.0–7.0

Conductivity (μS/cm)  at 25oC, max

0.1

1.0

5.0

Oxidisable matter Oxygen content (mg/l), max

–

0.08

0.4

Absorbance at 254 nm and 1 cm optical path length, absorbance units, max.

0.001

0.01

–

Residue after evaporation on heating at 110oC (mg/kg), max

–

1

2

Silica (SiO2) content (mg/l), max

0.01

0.02

–

American Society for Testing and Materials (ASTM)

The ASTM uses D1193-06 and has four grades of water (see table below).

Water quality parameters for ASTM types

Parameter

Type I*

Type II**

Type III***

Type IV

Conductivity (μS/cm) at 25oC, max

0.056

1.0

0.25

5.0

Resistivity (MΩ-cm) at 25oC, max

18.0

1.0

4.0

0.2

pH at 25oC

–

–

–

5.0–8.0

TOC (μg/l), max

50

50

200

No limit

Sodium (μg/l), max

1

5

10

50

Silica (μg/l), max

3

3

500

No limit

Chloride (μg/l), max

1

5

10

50

*Requires use of 0.2 μm membrane filter; **Prepared by distillation; ***Requires the use of 0.45 μm membrane filter.

As you can see, understanding choosing which pure water type you will use could quickly get confusing! Thankfully, when you get your water from an ELGA water purification system, you can rely upon it to deliver the level of purity your need, all while only keeping three main types in mind.

 

 

Pure Water Essence of the Lab Whitepaper download

How well do you know your ultrapure lab water?

Do you know the most effective way to use ultrapure water, your most fundamental reagent? Read our full whitepaper and discover how you can make sure that your pure water supply delivers the performance you need to produce reliable and accurate results.

          Read the Whitepaper

 

 

  • Enquiry
  • Consigue una cotización
  • Reserve una demo
  • Encuentre un socio aprobado

Enquiry

Please check this to confirm that you have read our Terms of Service and Privacy Policy.

Consigue una cotización

Please check this to confirm that you have read our Terms of Service and Privacy Policy.

Reserve una demo

Please check this to confirm that you have read our Terms of Service and Privacy Policy.

Call us

Can't find what you are looking for?

Support Number
+44 (0)20 3567 7300
United Kingdom Sales
+44 (0)1628 879 704
United States of America Sales
+1 877-315-3542
France Sales
+33 1 40 83 65 00
China Sales
+86 400-616-8882

 

Sede central de ELGA LabWater

Lane End Business Park
Lane End, High Wycombe
HP14 3BY
Reino Unido
Tel.: +44 (0) 203 567 7300
F: +44 (0) 203 567 7205

Los especialistas en agua ultrapura

  • Soporte y servicios
  • Eventos

Casos prácticos

  • Abbott Diagnostics
  • Diagnóstico médico de DASA
  • Instituto Médico NeoDIN
  • Fundación del NHS de North Staffordshire
  • Escuela técnica de Olsberg

Recursos

  • Obtenga más información sobre el agua ultrapura
  • Manuales e informes técnicos
  • Tecnologías de purificación
  • Aplicaciones
  • Impurezas en el agua

Blogs

  • Latest Blog
  • Water Purity - Different Types of Pure Water
  • What is Clinical Laboratory Reagent Water (CLSI)?
  • What is Total Organic Carbon (TOC)?
  • Idioma
    • Deutsch
    • English
    • Español
    • Français
    • Italiano
    • Português
    • 日本語
    • 中文
  • Otros sitios de Veolia
    • Veolia
    • Veolia Fondation
    • Veolia Water Technologies

© VWS (UK) Ltd. comercializado como ELGA LabWater.2021-Todos los derechos reservados.
ELGA es la marca mundial de agua de laboratorio de Veolia.

  • Política de privacidad
  • Términos y condiciones
  • Cumplimiento legal internacional
  • Patentes
  • Aviso legal
Elga Veolia
TOP

© 2017 ELGA Veolia